What performance should I expect from my MTP connection? The chart on our MT Ferrule product page, lists the maximum Insertion Loss (IL) and Return Loss (RL) you should expect for each ferrule grade. However, improper use or termination can degrade these values. MTP performance is primarily driven by three factors: 1. Selecting Quality Connector […]
TOPICS
Application of LSZH Cable
Why we need LSZH Fiber Cable The clearest uses for LSZH are confined spaces with large amounts of cables in close proximity to humans or sensitive electronic equipment. Submarines and ships are classic examples, which is why the military was one of the first adopters of LSZH standards. Additionally, mass transit and central office facilities […]
HISTORY OF LSZH MATERIALS
Even though they are still predominant in the industry, the use of halogenated compounds in wire and cable has decreased over the past several years. Polymers such as PVC are being phased out in certain applications, especially in enclosed, high-density cable applications. Relatively new low-smoke and zero (or low) halogen compounds, which are typically polyolefin […]
Data center cabling, network migration
Anixter’s recently produced Data Center Network Migration video details the complexities in data center cabling topology and design, and asks the question, “Is your physical cabling infrastructure designed to withstand constant change?” Anixter asserts that the four best practices needed to achieve a high-performance, future-ready structured cabling solution for a data center include: creating network […]
Practical Considerations of DWDM Deployment
Based on bit rate alone, DWDM has a fourfold advantage even over the latest—albeit nascent—TDM option, STM–64/OC–192. To fairly compare the two technologies, however, we need to review and outline what would be an ideal technological solution for expanding network capacity. This has to be done in a broad sense, recognizing that there are instances […]
Purpose and Scope of the X2 MSA
This Multi-Source Agreement (MSA) defines X2, a compact 10 Gigabit/s optical transceiver. The MSA should be regarded as a supplement to the XENPAK MSA and does not attempt to re-specify areas already covered by XENPAK. Every attempt has been made to make this document succinct and contain only information required to make or use the […]
Some of the key trends to watch for in 2015 are
Trend #1: Disaster prevention Key strategies such as business continuity and disaster prevention are expected to gain significant importance in the future. Many organizations have a strong awareness of possible failures both in terms of man-made and natural disasters. Trend #2: Shift to Internet data centers In 2015, organizations across the globe will be shifting […]
MTP I.B.C. Cleaner (MPO/MTP Connectors Only)
Use MTP I.B.C. P/N 7104 for either male or female connectors. 3.2.1 Open the dust cap lid on the MTP I.B.C. cleaner. 3.2.2 Insert the MPO/MTP connector into the dust cap. 3.2.3 Rotate the tape feeder wheel in the direction indicated on the cleaner. 3.2.4 Remove the connector from the cleaner tip. Close the dust […]
IPTV Home Applications and Services
Some key applications for initial IPTV deployment are the delivery of digital broadcast television and userselected video on Demand (VoD). These applications enable service providers to begin offering the “triple play” – video, voice and data. Additional video applications, which can be enabled after the IPTV infrastructure is in place, are also mentioned below. Some […]