IFS-10 Fusion Splicer Troubleshooting Power supply • Power does not turn off when pressing ⊙: Press and hold the key until the LED color changes from green to red. • Few splices can be made with a fully charged battery pack: •If the power saving function is not enabled, battery power degrades faster. Refer to […]
Fiber Splicing
How to splice fiber by Inno IFS-10 Fusion Splicer
How to splice fiber optic cable This section is a detailed introduction about how to splice two fibers together to become a single core fiber. the instruction divided into several section, please refer the list as follow: 1. Preparing the splicer 2. Preparing the fiber 3. How to make a splice 4. How to check […]
Fusion Splicer Error message list
Sumitomo Fusion Splicer Error Message List Please contact maintenance service center when it is not recovered if you take the measures below. Error message Description and measure Alignment Error (L)(R)(LR) [Description] There is dust in the V-groove. There is dust on the fiber. [Measure] Clean the V-groove. Re-cleave the fiber. Brightness Error Brightness Various Error […]
Maintenance of FSM-11S SpliceMate Splicing Quality
Maintenance of Splicing Quality 1. Cleaning and Checking before Splicing Critical cleaning points and maintenance checks are described below . 1-1. Arc Power Calibration Refer to [Arc Calibration] (Page 42). 1-2. Cleaning V -grooves If contaminants are present in the V -grooves, proper clamping may not occur, resulting in higher splice loss. The V -grooves […]
AFL/Fujikura FSM-60S Fusion Splicer Calibration
Arc Calibration & Motor Calibration 1>. Arc Calibration Atmospheric conditions such as temperature, humidity, and pressure are constantly changing, which creates variability in the arc temperature. This splicer is equipped with temperature and pressure sensors that are usedin a constant feedback monitoring control system to regulate the arc power at a constant level. Changes in […]
SUMITOMO Fusion Splicer Trouble Shooting
For repair and technical support, contact maintenance service center address described in the back cover. Arc problems The electrodes typically need replacement after 1000 splices. Some common symptoms that indicate the electrodes need replacing are: Fluttering or unstable arc observed on the monitor Sizzling noise while arcing Bubbles in the fibers after splicing Fiber burned […]
Important tips for using fusion splicer
Read this before using the fusion splicer Fusion Splicer Setting Up 1. This fusion splicer performs an arc discharge. Do not use the splicer in a hazardous location in which inflammable gas can generate or only electrical apparatus for explosive gas atmosphere can be used. 2. Never use spray cleaners such as Freon or Flammable […]
Fujikura FSM-70R Rribbon Fusion Splicer
Fujikura FSM-70R Mass Fiber Fusion Splicer The Fujikura 70R is a fully robust fusion splicer for ribbon optical fibre. The new design streamlines the steps required to complete splices, resulting in greater productivity. The ‘configurable automation’ features allow you to customise the operation of the machine to best suit your particular splicing technique and process. […]
Fujikura FSM-80S, 80S Fusion Splicer
Fujikura FSM-80S Fusion Splicer Introduction FSM-80S is core-to-core alignment single fiber splicer succeeding to 60S. In addition to ruggedized concept, which 60S created, the 80S has a series of new features, such as “Automated wind-protector and tube-heater” for quicker splicing cycle as well as fewer operation steps, “innovative carrying-case design” for quicker preparation, “powerful Li-ion […]
Fujikura FSM-60R Fusion Splicer
Fujikura FSM-60R Fusion Splicer Fujikura FSM-60R 12 Mass Fusion Splicer’s leading-edge features, including unprecedented size, weight, and ruggedness, make it the first core-alignment splicer truly optimized for field use, including FTTH applications. Automation such as calibration-free arc (with AUTO splice mode), automatic fiber identification and reduced operational steps, provides ease of use. In addition, the […]